The Alpha-Stim 100
Life Can Be Brutal...Why Suffer?

Freedom from Pain...of the Body and
Mind
Absolutely nothing relieves pain,
anxiety, depression, and/or insomnia like the
Alpha-Stim 100. Inspired by recent advances in our
understanding of biophysics, the Alpha-Stim 100’s
therapeutic abilities have been acclaimed by health
care professionals and patients world wide. Results
gained from the Alpha-Stim 100 have been repeatedly
verified through more clinical studies than with any
other device in its class.
Treating Pain With
MET
|
The Alpha-Stim 100 uses microcurrent
electrical therapy (MET) for those suffering
from acute, chronic or postoperative pain.
The Alpha-Stim 100 works with the body on a
large variety of ailments, including
difficult-to-treat problems. Alpha-Stim 100
microcurrent technology produces residual
and cumulative results, far superior to
previous traditional milliampere
transcutaneous electrical nerve stimulation
(TENS) devices. Turn a TENS off and the pain
returns. Although broadly classified as a
TENS, the Alpha-Stim 100 is significantly
superior because MET works with tiny
currents, closer to the type and amount of
electricity that naturally occurs in the
body. By comparison, the electric current
used by typical TENS devices is thousands of
times greater than natural body current.
Although a slight tingling sensation is
sometimes felt under the electrodes, it is
not necessary to feel this in order to
achieve results. Many people feel nothing at
all with the Alpha-Stim 100 except positive
results. MET is applied through easy to use
probes or self-adhesive electrodes. Specific
treatment protocols are included with the
Alpha-Stim 100 and technical assistance is
readily available by telephone, fax, e-mail
or mail. Alpha-Stim technology is backed by
more independent research than any other
device in its class. Electromedical Products
International, Inc. has been in business
since 1981, treating a wide variety of
medical disorders with Alpha-Stim
microcurrent technology during that time
with no reports of significant side effects. |
 |
Treating Anxiety, Depression, and/or Insomnia with
CES
|
|
The Alpha-Stim 100 treats anxiety,
depression, and/or insomnia with
microcurrent using a method called
cranial electrotherapy stimulation
(CES). The treatment is very simple. The
current is applied by easy to use clip
electrodes that attach on the ear lobes.
Used just 20 to 40 minutes every day,
every other day, or on an as-needed
basis, it can help induce a pleasant,
relaxed feeling of well being. The
Alpha-Stim 100 is well tolerated and
very safe in contrast to drugs used in
the treatment of mood disorders, many of
which have been proven to have
undesirable side effects and can be
addictive. Unlike drugs, the Alpha-Stim
100 leaves the mind alert. Anxiety
reduction is usually experienced during
treatment. Depression and insomnia
control is generally experienced after
one to two weeks of daily treatment. CES
can also help treat the underlying mood
disorders associated with pain.
It may be used as an adjunct to
medication and/or psychotherapy. After
treatment, there are usually no physical
limitations imposed so the majority of
people can resume normal activities
immediately. Maintenance of a relaxed,
yet alert state is generally achieved
with treatments three times per week. As
a result, the Alpha-Stim 100 is suitable
for clinical or home use.
|
Frequency Display
EEG Before Treatment
This first chart
shows a typical pain patient’s brain waves
averaged over two minutes. This is an
abnormal frequency pattern.
|
|
EEG After Treatment
This second chart was taken from the same
patient after 10 minutes of Alpha-Stim use.
It shows beneficial smoothing of the brain
waves to a normal pattern. |
From
research by Dr. Michael Heffernan. Comparative
Effects of Microcurrent Stimulation on EEG Spectrum
and Correlation Dimension. From the journal
Integrative Physiological and Behavioral Science,
31(3):202-209, 1996.
How does the Alpha-Stim
100 Work?
The
Alpha-Stim 100 is distinct in that it is
based on the concept that the biophysics
underlying the body’s biochemistry also
plays a significant role in regulating
all of life’s processes. Doctors are
taught that there are about 75 trillion
cells in a human body, each having an
electrical potential across its cell
membrane, similar to a battery.
Alpha-Stim’s proprietary waveform works
by moving electrons through the body and
brain at a variety of frequencies,
collectively known as harmonic
resonance. This normalizes the
electrical activity of the nervous
system and brain as measured by an
electroencephalogram (EEG).
|
 |
What Scientific Research Has Been Conducted?
At present, there are
over 100 research studies on CES in humans, and 20
experimental animal studies. The overwhelming
majority of the scientific research is extremely
positive. No significant lasting side effects have
been reported. In a recent survey, health care
practitioners reported the following results using
Alpha-Stim technology:

Who Developed the Alpha-Stim 100?

Dr. Daniel L. Kirsch
|
The Alpha-Stim 100 was developed by
neurobiologist Dr. Daniel L. Kirsch and
consultant engineers. Dr. Kirsch has been a
leading pioneer in the field of
electromedicine since 1972. He is a Fellow
of the American Institute of Stress, a
Diplomate of the American Academy of Pain
Management and a Fellow of the Clinical
Electromedical Research Academy. Dr. Kirsch
has served as Clinical Director of the
Center for Pain and Stress-Related Disorders
at Columbia-Presbyterian Medical Center in
New York City and the Sports Medicine Group
in Santa Monica, California. He lectures
frequently to physicians worldwide on pain
and stress management. Alpha-Stim technology
is backed by more independent research than
any other device in its class. There have
been no reports of significant side effects
from any Alpha-Stim device. Only original
Alpha-Stim products meet Electromedical
Products International, Inc.’s exacting
specifications. |

The Alpha-Stim 100 is packaged complete with one set
of 4 self-adhesive AS-Trode™ brand silver electrodes
(good for approximately 2 weeks to 1 month of use),
electrode wires, 2 probes, ear clip electrodes, 200
felt electrodes for use with the probes and ear
clips, a 15 ml bottle of Alpha Conducting Solution™
(ACS), a 9 volt battery, carrying case, and
illustrated Owner’s Manual. This is everything
necessary to begin to use the Alpha-Stim 100 right
away. Replace self-adhesive and felt electrodes only
with authorized Alpha-Stim and AS-Trode™ brand
products.
Five Year Warranty :
Each Alpha-Stim 100 is warranted to be free from
defects in materials and workmanship under normal
use for a period of five years except for
replacement of batteries and accessories. See
Owner’s Manual for complete details.
Technical Specifications
|
Electrical |
| Power Source |
One 9 volt
battery (included). Replace with disposable
batteries (alkaline preferred). |
| Timer Settings |
Probe (10 seconds
on, alternating with 2 seconds off), 10, 20,
60 minutes, and continuous. |
| Current |
10 to 600 µA continuously adjustable. |
| Frequency |
0.5, 1.5, or 100 Hz (pulses per second). |
| Waveform |
Bipolar asymmetric rectangular waves, 50%
duty cycle, 0 net current (see graphic
depiction above). |
| Mechanical |
|
| Height |
13.5 cm |
| Width |
6.4 cm |
| Depth |
3.3 cm including belt clip |
| Weight |
156gm with battery |
| Carrying Case |
|
| Height |
20.8 cm |
| Width |
26.9 cm |
| Depth |
4.6 cm |
| Shipping Weight With Unit |
0.91 kg |
Presribing Information
CE
conformity statement for Europe:
The
Alpha-Stim 100 is a class IIa, Type B medical
device. It has been independently tested by outside
agencies in order to provide assurance of conformity
to applicable standards for medical equipment safety
and electromagnetic compliance.
Caution statement
for United States: Federal Law (USA only)
restricts this device to sale by, or on the order of
a licensed health care practitioner. Outside of the
USA it is available world wide without a
prescription but consultation with a qualified
health care professional is recommended for
difficult and unresponsive problems or when used in
conjunction with pharmaceuticals or other
therapeutic intervention.
Indications: Alpha-Stim 100
cranial electrotherapy stimulation (CES) technology
is continuously being subjected to rigorous study
and evaluation by the international medical
community. Findings to date indicate that the
Alpha-Stim 100 is an effective treatment with broad
applications for a variety of syndromes involving
pain, and for the management of anxiety, depression,
and/or insomnia, or for the short term relief of the
symptoms of pain, anxiety, depression and/or
insomnia. In many cases it is the sole therapeutic
method required. Effective results in pain
management have been seen during and/or subsequent
to stimulation over affected body parts, adjacent
areas, and areas distant from those in pain. As with
any therapeutic intervention, not all people will
respond to the Alpha-Stim 100. The degree of
efficacy will vary with the nature of the problem
being treated, the overall health of the person, and
with the method of treatment.
Contraindications: The
Alpha-Stim 100 may effect the operation of cardiac
pacemakers (particularly demand type pacemakers). Do
not stimulate directly on the eyes, or over the
carotid sinus (on the neck beside the larynx).
Precautions: For external use only. Do not
allow children to use or handle this device without
adult supervision. Do not operate potentially
dangerous machinery or vehicles during, and in some
cases, for several hours after treatment. Caution is
advised in cases where other forms of analgesia
(pain control) would not be used; such as to retain
the beneficial aspects of pain for diagnosis or in
cases where people may overuse pain-controlled
areas. Safety of stimulation has not been
established during pregnancy. There have been
isolated reports of blood pressure being lowered by
CES so care should be taken while using the
Alpha-Stim 100 with high blood pressure medication.
Adverse
Effects: Adverse effects are usually mild
and self-limiting. Adverse effects seen in
approximately 4,541 patients in controlled, open,
uncontrolled conditions, and by physician survey and
reasonably associated with the use of CES are
dizziness (6 cases, 0.13%), skin
irritation/electrode burns (5 cases, 0.11%), and
headaches (9 cases, 0.20%). Prolonged CES treatment
at higher than necessary currents may cause
dizziness or nausea that can last from hours to
days. Treatment immediately prior to going to sleep
may cause difficulty sleeping due to increased
alertness. It is recommended that CES be used at
least 3 hours before going to sleep. Paradoxical
reactions such as hyperexcited states, increased
anxiety, and sleep disturbances may occor.